Digital pressure switch, type MP48E with threads G1/8“ and M5 |
|||||
|
Order codes
Technical data
| Description | Value |
| Rated pressure range [MPa] | -0,1 to 1,0 |
| Thread | G1/8“ external and M5 internal |
| Max. pressure [MPa] | 1.5 |
| Working medium | air, non-corrosive gases, incombustible gases |
| Supply voltage [V] | 15 to 24, DC (± 10%) |
| Current consumption [mA] | ≤40 (no load) |
| Comparative output | 2x PNP/NPN output, current max. 150 mA, voltage max. 30V DC, residual voltage ≤1V |
| Comparative output indication | orange indicator for both outputs |
| Analog voltage output | output voltage 0 to 10 V or 1 to 5 V ±0,5%, linearity ±0,5% F.S., output impedance approx. 2 kΩ |
| Analog current output | output current 4 to 20 mA ±0,5%, linearity ±0,5% F.S., load impedance: min. 50 Ω, max. 250 Ω at 15 V, max. 600 Ω at 24 V |
| Communication interface | RS485 Modbus RTU |
| Units and resolution | MPa: 0,001, bar, kgf/cm2: 0,001, PSI: 0,01 |
| Hysteresis | adjustable, 8 digit in one point set mode and window comparator mode |
| Repeatability | ±0,2% F.S. ±1 digit |
| Indicator accuracy | ±0,5% F.S. ±1 digit (at 25 ±3°C) |
| Temperature characteristic | ±0,5% F.S. of detected pressure (25°C) at range 0 to 50°C |
| Response time [ms] | adjustable 6 to 3000 in 8 steps |
| Short circuit protection | integrated |
| Display | 4 ½ digits, 7 segments, red/white/pink/orange, sampling rate 0,2, 0,5, 1 s / time |
| Enclosure | IP40 |
| Ambient temperature range [°C] | 0 to +50 (no condensation or freezing), storage: -10 to +60 |
| Ambient humidity [%] | 35 to 85 |
| Cable | 5-wire, section 0,15 mm2, length 2m, removable, ∅4 mm, PVC-26AWG |
| Weight [kg] | 0,067 incl. cable |
Wiring diagrams
Output 010: 2x NPN + 1 analog output 1-5V |
Output 011: 2x NPN + 1 analog output 4-20mA |
|
Output 030: 2x PNP + 1 analog output 1-5V |
Output 031: 2x PNP + 1 analog output 4-20mA |
|
Output 02R: 1x NPN + RS485 |
Output 04R: 1x PNP + RS485 |
Dimensions
Accessories
Bracket A22 |
Bracket A23 |
|
Panel mounting adapter with protective cover C2 |
||
| Dimensions of panel mounting adapter without protective cover. It is necessary to create square hole with dimensions 31x31 mm. Max. panel thickness is 4,5 mm. | ||